393 products
-
CAD-150 Control Panels - Red CAD-150-1 (R)
Non expandable 1 loop and compact addressable fire alarm control panel. Up to 250 addresses (detectors, modules, sounders or manual call points). Self-search and self-diagnosis function. 250 programmable zones, 20 alarm and fault display zones via LEDs, 6.000 event log, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 voltage-free relay outputs configurable on board. LCD graphic display. 24V 500 mA auxiliary output. ABS plastic cabin with the possibility of recessing. Multilingual keyboard. Connectable to S-Network (up to 32 nodes) of control panels and repeaters via RS485 or fiber optics.
-
CAD-150 Control Panels - Red CAD-150-2 (R)
Non expandable 2 loops and compact addressable fire alarm control panel. Up to 500 addresses (detectors, modules, sounders or manual call points). Self-search and self-diagnosis function. 250 programmable zones, 20 alarm and fault display zones via LEDs, 6.000 event log, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 voltage-free relay outputs configurable on board. LCD graphic display. 24V 500 mA auxiliary output. ABS plastic cabin with the possibility of recessing. Multilingual keyboard. Connectable to S-Network (up to 32 nodes) of control panels and repeaters via RS485 or fiber optics.
-
CAD-150 Control Panels - Red CAD-150-2-MB (R)
Non expandable 2 loops and compact addressable fire alarm control panel. Up to 500 addresses (250 adresses per loop: detectors, modules, sounders or manual call points). Self-search and self-diagnosis functions. 250 programmable zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. Metal box. Multilingual keyboard. Able to be networked to S-Network (32 nodes) via RS485 or fiber optics.
-
CAD-150 Control Panels - Red CAD-150-4 (R)
Non expandable 4 loops and compact addressable fire alarm control panel. Up to 1.000 addresses (250 addresses per loop: detectors, modules, sounders or manual call points). Self-search and self-diagnosis functions. 250 programmable zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500mA. Metal box. Multilingual keyboard. Able to be networked to S-Network (32 nodes) via RS485 or fiber optics.
-
CAD-150 Control Panels - Red CAD-150-8 (R)
Addressable fire alarm control panel with 4 loops expandable up to 8 loops, by means of 2 additional loops cards (TBUD-150). Up to 2,000 addresses (250 addresses per loop: detectors, modules, sounders or manual call points). Auto-search function, 250 programmable zones, 40 alarm and fault display zones via leds, 6.000 event history logs, free configuration and maintenance software, USB port configuration, 2 supervised sounder outputs and 2 free relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. Able to be networked to S-Network (32 nodes) via RS485 or fiber optics.
-
CAD-150 Control Panels - Red CAD-150-8-PLUS (R)
Addressable fire alarm control panel with 4 loops expandable up to 8 loops with printer built-in, by means of 2 additional loops card (TBUD-150). Up to 2,000 addresses (250 addresses per loop: detectors, modules, sounders or manual call points). Auto-search function, 250 programmable zones, 40 alarm and fault display zones via leds, 6.000 event history logs, free configuration and maintenance software, USB port configuration, 2 supervised sounder outputs and 2 free relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. Modbus output for integrations, compatible with Detnov Cloud and Detnov Remote Center (remote maintenance and remote control).
-
CAD-150 Panels with Printer CAD-150-4-P
Four-loop CAD-150 addressable panel with built-in printer and S-Network communication.
-
CAD-150 Panels with Printer CAD-150-8-P
Four-loop CAD-150 panel expandable to 8 loops with built-in printer.
-
CAD-150 Panels with Printer CAD-150-8-PLUS-P
Expandable 8-loop CAD-150 PLUS panel with built-in printer.
-
CAD-150 / CAD-151 Repeaters CAD-150-R-LT
Bidirectional S-Network repeater for CAD-150 and CAD-151 systems, supporting up to 32 nodes.
-
CAD-150 Accessories TBUD-150
Two-loop expansion card providing up to 500 additional addresses for expandable CAD-150 panels.
-
CAD-150 Accessories TED-151-CL
TCP/IP communication card for Detnov Cloud, Remote Center and Modbus connections.
-
CAD-150 Accessories TED-151-2PE
TCP/IP and RS485 communication card supporting Detnov Cloud, Remote Center and Modbus integration.
-
CAD-150 Accessories TMB-251-LT
CAD-150 Ethernet and isolated S-Network RS485 communication card.
-
CAD-150 Accessories TMB-251
CAD-150 communication card with Ethernet, S-Network, Modbus RS485 and serial printer interface.
-
CAD-150 Accessories TMBFI-251
Fibre-optic communication card for CAD-150 S-Network installations.
-
CAD-150 / CAD-151 Common Accessories TCD-107-5G
EN 54-21 transmitter kit for CAD-150 installations without S-Network capability.
-
CAD-150 / CAD-151 Common Accessories TCD-108-5G
EN 54-21 transmitter kit including TMB-251 for network-capable CAD-150 systems.
-
CAD-150 / CAD-151 Common Accessories PGD-300C
Hand-held loop analyser and address programmer for compatible Detnov addressable devices.
-
CAD-150 / CAD-151 Common Accessories CUSB-150
USB configuration cable for CAD-150, CAD-151 and CAD-250 addressable control panels.
-
CAD-150 / CAD-151 Common Accessories SCD-150
Configuration, commissioning and maintenance software for CAD-150 and CAD-151 control panels.
-
CAD-150 / CAD-151 Common Accessories SGD-RCD
Remote Center application for remote service access to compatible CAD-150 and CAD-151 panels.
-
Addressable Detectors DOD-320A
Addressable smoke detector, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200). Up to 5 configurable sensitivity profiles, manufacturing date and usage time recording. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. CPR certificate EN 54-7. Dimensions: 100 x 40 mm IP40.
-
Addressable Detectors DOTD-330A
Addressable smoke & heat detector, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Heat function (A2R). White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm. IP40.
-
Addressable Detectors DTD-310A
Addressable heat detector, incorporates verification algorithms. LED status and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200). By means of the PGD-300 programming tool can be configured with up to 5 classes A1, A2R (by default, A2S, BR and BS. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. CPR certificate EN 54-5. Dimensions: 100 x 40 mm. IP40.
-
Addressable Detectors DOD-220A
Addressable smoke detector, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7. Dimensions: 100 x 40 mm.
-
Addressable Detectors DOTD-230A
Addressable smoke & heat detector, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm.
-
Addressable Detectors DTD-210A
Addressable heat (58°C fixed temperature and thermal rate of rise) detector, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Allows installation without polarity. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
-
Addressable Detectors DTD-215A
Addressable high temperature detector (fixed at 78ºC), with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Allows installation without polarity. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
-
Addressable Detectors DOD-320A-I
Addressable smoke detector with built-in isolator, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer, anti-theft system (only with Z-200). Up to 5 configurable sensitivity profiles, manufacturing date and usage time recording. White color. Requires connection base Z-200 or Z-200-H. CPR certificates EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
Addressable Detectors DOTD-330A-I
Addressable smoke & heat detector with built-in isolator, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Heat function (A2R). White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
Addressable Detectors DTD-310A-I
Addressable heat detector, incorporates verification algorithms with built-in isolator. LED status and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200). By means of the PGD-300 programming tool can be configured with up to 5 classes A1, A2R (by default, A2S, BR and BS. White color. Requires connection base Z-200 or Z-200-H. CPR certificates EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
Addressable Detectors DOD-220A-I
Addressable smoke detector with built-in isolator, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
-
Addressable Detectors DOTD-230A-I
Addressable smoke & heat detector with built-in isolator, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
-
Addressable Detectors DTD-210A-I
Addressable heat (58°C fixed temperature and thermal rate of rise) detector with built-in isolator, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
-
Addressable Detectors DTD-215A-I
Addressable high temperature detector (fixed at 78ºC) with built-in isolator, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
-
Addressable Detectors DOD-320A-B
Addressable smoke detector, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200-B). Up to 5 configurable sensitivity profiles, manufacturing date and usage time recording. Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. CPR certificate EN 54-7. Dimensions: 100 x 40 mm. IP40.
-
Addressable Detectors DOTD-330A-B
Addressable smoke & heat detector, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Heat function (A2R). Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200-B). CPR certificates EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm. IP40.
-
Addressable Detectors DTD-310A-B
Addressable heat detector, incorporates verification algorithms. LED status and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200). By means of the PGD-300 programming tool can be configured with up to 5 classes A1, A2R (by default, A2S, BR and BS. Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
-
Addressable Detectors DOD-220A-B
Addressable smoke detector, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7. Dimensions: 100 x 40 mm.
-
Addressable Detectors DOTD-230A-B
Addressable smoke & heat detector, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm.
-
Addressable Detectors DTD-210A-B
Addressable heat (58°C fixed temperature and thermal rate of rise) detector, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Allows installation without polarity. Requires base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
-
Addressable Detectors DTD-215A-B
Addressable high temperature detector (fixed at 78ºC), with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200.. Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
-
Addressable Detectors DOD-320A-I-B
Addressable smoke detector with built-in isolator, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200-B). Up to 5 configurable sensitivity profiles, manufacturing date and usage time recording. Black color. Requires connection base Z-200-B or Z-200-B-H. CPR certificates EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
Addressable Detectors DOTD-330A-I-B
Addressable smoke & heat detector with built-in isolator, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Heat function (A2R). Black color. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200-B). CPR c ertificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
Addressable Detectors DTD-310A-I-B
Addressable heat detector with built-in isolator, incorporates verification algorithms. LED status and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200). By means of the PGD-300 programming tool can be configured with up to 5 classes A1, A2R (by default, A2S, BR and BS. Black color.Requires connection base Z-200-B or Z-200-B-H. CPR certificates EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
Addressable Detectors DOD-220A-I-B
Addressable smoke detector with built-in isolator,, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
-
Addressable Detectors DOTD-230A-I-B
Addressable smoke & heat detector with built-in isolator, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
Not sure which part you need?
Our technical team helps with system design, product selection and compatibility. Approved installation companies can also download datasheets and request quotations online.