393 products
-
Addressable Detectors DTD-210A-I-B
Addressable heat (58°C fixed temperature and thermal rate of rise) detector with built-in isolator, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
-
Addressable Detectors DTD-215A-I-B
Addressable high temperature detector (fixed at 78ºC) with built-in isolator, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
-
Addressable Detector Accessories BUD-200
Buzzer for addressable detectors series 200A, 300 and 300A.
-
Addressable Linear Smoke Detection DBD-70XA-I
Addressable motorized beam smoke detector with a range of 70 meters extendable up to 140 or 160 meters by means of extension kits. Separate detector and controller for easy access to programming. IP65 for use in extreme environmental conditions. Loop powered. CPR EN 54-12, EN 54-17, EN 54-18 certified. Dimensions: detector 180 x 155 x 137 mm, controller 185 x 120 x 62mm.
-
Addressable Manual Call Points MAD-452
Addressable manual call point. Includes protection cover TBD-200, surface suplement SMD-200 and test key RKEY- 200. Surface installation. Indoor use. Red color. CPR certificate EN 54-11. Dimensions: 85 x 89 x 35 mm.
-
Addressable Manual Call Points MAD-452-I
Addressable manual call point with built-in isolator. includes protection cover TBD-200, surface suplement SMD-200 and test key RKEY-200. Surface installation. Indoor use. Red color.CPR certificates EN 54-11 and EN 54-17. Dimensions: 89 x 85 x 60 mm.
-
Addressable Manual Call Points MAD-452-5ST
5 Addressable manual call point pack. Includes surface suplement SMD-200 and test key RKEY-200.Not includes protection cover TBD-200. Surface installation. Indoor use. Red color. CPR certificate EN 54-11. Dimensions: 89 x 85 x 60 mm per unit
-
Addressable Manual Call Points MAD-452-I-5ST
5 Addressable manual call point with built-in isolator. Includes surface suplement SMD-200 and test key RKEY-200. Not ncludes protection cover TBD-200. Surface installation. Indoor use. Red color.CPR certificates EN 54-11 and EN 54- 17. Dimensions: 89 x 85 x 60 mm.
-
Addressable Manual Call Points MAD-451-I
Addressable manual call point with built-in isolator. LED status indicator and test key. Red color. CPR certificates EN 54-11 and EN 54-17. Dimensions: 85 x 85 x 55 mm.
-
Addressable Sounders and Beacons MAD-600-CVS-I-W
Ceiling addressable sounder base with Visual Alarm Device and built-in isolator. White cap color. Compatible with 200A and 300A series detectors. Acoustic power up to 90 dB/1m depending on the selected tone. It occupies one address in the loop. C-3-9 coverage. 32 configurable tones. Powered by the loop or from external 24 Vcc EN 54-4 power supply. IP21. White color. CPR certificates EN 54-3, EN 54-23 and EN 54-17. Dimensions: 145 X 40 mm. Requires Z-200 base (not included). Check product availability.
Check availability
-
Addressable Sounders and Beacons MAD-600-CS-I-W
Ceiling addressable sounder with built-in isolator. White cap color. Compatible with 200A and 300A series detectors. Acoustic power up to 90 dB/1m depending on the selected tone. It occupies one address in the loop. 32 configurable tones. Powered by the loop or from external 24 Vcc EN 54-4 power supply. IP21. Red color. CPR certificates EN 54-3 and EN 54-17. Dimensions: 145 X 40 mm. Check product availability..
Check availability
-
Addressable Sounders and Beacons MAD-600-CS-I-B
Ceiling addressable sounder with built-in isolator. Black cap color. Compatible with 200A and 300A series detectors. Acoustic power up to 90 dB/1m depending on the selected tone. It occupies one address in the loop. 32 configurable tones. Powered by the loop or from external 24 Vcc EN 54-4 power supply. IP21. Red color. CPR certificates EN 54-3 and EN 54-17. Dimensions: 145 X 40 mm. Check product availability.
Check availability
-
Addressable Sounders and Beacons MAD-600-WVS-I-R
Wall addressable sounder and visual alarm device base with built-in isolator. Red cap color. Compatible with 200A and 300A series detectors. Acoustic power up to 90 dB/1m depending on the selected tone. It occupies one address in the loop. 32 configurable tones. W-5-5 covergage. Powered by the loop or from external 24 Vcc EN 54-4 power supply. IP21. White color. CPR certificates EN 54-3, EN 54-23 and EN 54-17. Dimensions: 130 X 40 mm. Check product availability.
Check availability
-
Addressable Sounders and Beacons MAD-600-WS-I-W
Wall addressable sounder with built-in isolator. White cap color. Compatible with 200A and 300A series detectors. Acoustic power up to 90 dB/1m depending on the selected tone. It occupies one address in the loop. 32 configurable tones. Powered by the loop or from external 24 Vcc EN 54-4 power supply. IP21. Red color. CPR certificates EN 54-3 and EN 54-17. Dimensions: 130 X 40 mm. Check product availability.
Check availability
-
Addressable Sounders and Beacons MAD-600-WS-I-R
Wall addressable sounder with built-in isolator. Red cap color. Compatible with 200A and 300A series detectors. Acoustic power up to 90 dB/1m depending on the selected tone. It occupies one address in the loop. 32 configurable tones. Powered by the loop or from external 24 Vcc EN 54-4 power supply. IP21. Red color. CPR certificates EN 54-3 and EN 54-17. Dimensions: 130 X 40 mm. Check product availability.
Check availability
-
Addressable Sounders and Beacons MAD-461-I
Addressable loop sounder with isolator. Low power consumption, acoustic power 82.5 dB. It takes just one address in the loop. Color red. For indoor use. IP21. CPR certificate EN 54-3 and EN 54-17. Dimensions: 65 x 90 mm.
-
Addressable Sounders and Beacons MAD-464-I
Addressable loop sounder with built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power from 78.3 dBA to 104.6 dBA depending on the selected tone. It takes just one address in the loop. Red color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm.
-
Addressable Sounders and Beacons MAD-465-I
Addressable loop sounder with beacon and built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power 76 dBA to 117 dBA depending on the selected tone. It takes just one address in the loop. Red color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm.
-
Addressable Sounders and Beacons MAD-464-I-W
Addressable loop sounder with built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, edium, High). Acoustic power from 78.3 dBA to 104.6 dBA depending on the selected tone. It takes just one address in the loop. White color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm.
-
Addressable Sounders and Beacons MAD-465-I-W
Addressable loop sounder with beacon and built-in isolator. Low power consumption. 32 tones and 3 configurable volumes (Low, Medium, High). Acoustic power 76 dBA to 117 dBA depending on the selected tone. It takes just one address in the loop. White color. IP33C. Deep base. CPR certificate EN 54-3 and EN 54-17. Dimensions: 100 x 75 mm.
-
Addressable Sounders and Beacons MAD-564-I
Addressable loop sounder with built-in isolator. Acoustic power 95 dB to 100 dB according with tone and connection mode, 32 tones and 4 optional volumes. It takes just one address in the loop. It can be powered through the loop or by an external power supply EN 54-4. Color red. IP65. Deep base CPR certificate EN 54-3 and EN 54-17. Dimensions: 63 x 118 x 121 mm.
-
Addressable Sounders and Beacons MAD-565-I
Addressable loop sounder with beacon and built-in isolator. Acoustic power 95 dB to 100 dB according with tone and connection mode, 32 tones and 4 optional volumes. It takes just one address in the loop. It can be powered through the loop or by an external power supply EN 54-4. Color red. IP65. Deep base CPR certificate EN 54-3, EN 54-23 and EN 54-17. Coverages W4-9 and W3-7. Dimensions: 63 x 118 x 121 mm.
-
Addressable Sounders and Beacons MAD-564-I-W
Addressable loop sounder with built-in isolator. Low power consumption, acoustic power 95 dB to 100 dB according with tone and connection mode, 32 tones and 4 optional volumes. It takes just one address in the loop. It can be powered through the loop or by an external power supply EN 54-4. Color white. IP65. Deep base CPR certificate EN 54-3 and EN 54-17. Dimensions: 63 x 118 x 121 mm.
-
Addressable Sounders and Beacons MAD-565-I-W
Addressable loop sounder with beacon and built-in isolator. Acoustic power 95 dB to 100 dB according with tone and connection mode, 32 tones and 2 optional volumes. It takes just one address in the loop. It can be powered through the loop or by an external power supply EN 54-4. Color white. IP65. Deep base CPR certificate EN 54-3, EN 54-23 and EN 54-17. Coverages W4-9 and W3-7. 63 x 118 x 121 mm.
-
Addressable Sounders and Beacons MAD-567-I
Addressable loop sounder base with built-in isolator. 200A series detector compatible. CPR. Acoustic power up to 92 dB according with tone and connection mode, 32 tones and 4 optional volumes. It takes just one address in the loop. It can be powered through the loop or by an external power supply EN 54-4. Color white. CPR certificate EN 54-3 and EN 54-17. Dimensions: 130 mm ø x 28 mm.
-
Addressable Sounders and Beacons MAD-567-I(NL)
Addressable loop sounder base with built-in isolator. 200A series detector compatible. CPR. Acoustic power up to 92 dB according with tone and connection mode, 32 tones and 4 optional volumes. It takes just one address in the loop. It can be powered through the loop or by an external power supply EN 54-4. Color white. CPR certificate EN 54-3 and EN 54-17. Dimensions: 130 mm ø x 28 mm.NL tone
-
Addressable Sounders and Beacons MAD-569-I
Addressable loop sounder base with beacon and built-in isolator. 200A and 300A series detector compatible. CPR. Acoustic power up to 92 dB according with tone and connection mode, 32 tones and 4 optional volumes. It takes just one address in the loop. It can be powered through the loop or by an external power supply EN 54-4. Color white. CPR certificate EN 54-3, EN 54-23 and EN 54-17. Coverages C3-15 and C3-9 Dimensions: 130 mm ø x 28 mm.
-
Addressable Sounders and Beacons MAD-569-I F
Addressable loop visual alarm device base and built-in isolator. 200A and 300A series detector compatible. CPR. It takes just one address in the loop. It can be powered through the loop or by an external power supply EN 54-4. Color white. CPR certificate EN 54-3, EN 54-23 and EN 54-17. Coverages C3-15 and C3-9 Dimensions: 130 mm ø x 28 mm.
-
Addressable Sounders and Beacons MAD-567-I-B
Addressable loop sounder base with built-in isolator. 200A series detector compatible. CPR. Acoustic power up to 92 dB according with tone and connection mode, 32 tones and 4 optional volumes. It takes just one address in the loop. It can be powered through the loop or by an external power supply EN 54-4. Color black. CPR certificate EN 54-3 and EN 54-17. Dimensions: 130 mm ø x 28 mm.
-
Addressable Sounders and Beacons MAD-567-I-B(NL)
Addressable loop sounder base with built-in isolator. 200A series detector compatible. CPR. Acoustic power up to 92 dB according with tone and connection mode, 32 tones and 4 optional volumes. It takes just one address in the loop. It can be powered through the loop or by an external power supply EN 54-4. Color black. CPR certificate EN 54-3 and EN 54-17. Dimensions: 130 mm ø x 28 mm. NL tone.
-
Addressable Sounders and Beacons MAD-569-I-B
Addressable loop sounder base with beacon and built-in isolator. 200A and 300A series detector compatible. CPR. Acoustic power up to 92 dB according with tone and connection mode, 32 tones and 4 optional volumes. It takes just one address in the loop. It can be powered through the loop or by an external power supply EN 54-4. Color black. CPR certificate EN 54-3, EN 54-23 and EN 54-17. Coverages C3-15 and C3-9 Dimensions: 130 mm ø x 28 mm.
-
Addressable Sounders and Beacons MAD-472
Addressable sounder base. 200A series detector compatible. CPR Certified EN 54-3. Acoustic power: 80dB. Indoor use. IP21C. It takes just one address in the loop. Dimensions: 150 x 100 mm.
-
Addressable Sounders and Beacons MAD-473
Addressable sounder base with beacon. 200A series detector compatible. CPR Certified EN 54-3. Acoustic power: 80dB. Indoor use. IP21C. It takes just one address in the loop. Dimensions: 150 x 100 mm.
-
Addressable Sounders and Beacons MAD-472-B
Addressable sounder base. 200A series detector compatible. CPR Certified EN 54-3. Acoustic power: 80dB. Indoor use. IP21C. It takes just one address in the loop. Dimensions: 150 x 100 mm. Black color.
-
Addressable Sounders and Beacons MAD-473-B
Addressable sounder base with beacon. 200A series detector compatible. CPR Certified EN 54-3. Acoustic power: 80dB. Indoor use. IP21C. It takes just one address in the loop. Dimensions: 150 x 100 mm. Black color.
-
Addressable Sounders and Beacons TBD-470
Protective cap for the MAD-472, MAD-473, MAD-567-I and MAD-569-I sounder bases.
-
Addressable Sounders and Beacons TSD-600-B
Protective cap for the MAD-600 and SCD-600 series sounder bases. Color black
-
Addressable Sounders and Beacons TSD-600-R
Protective cap for the MAD-600 and SCD-600 series sounder bases. Color red
-
Addressable Sounders and Beacons TSD-600-W
Protective cap for the MAD-600 and SCD-600 series sounder bases. Color white
-
Addressable Modules MAD-401
Addressable monitor module with 1 supervised technical input for device status indication providing NC or NO contact. It takes one address in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Non polarity installation. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
Addressable Modules MAD-402
Addressable monitor module with 2 supervised technical inputs for devices status signaling providing NC or NO contact. It takes two addresses in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
Addressable Modules MAD-411
Addressable control module for 1 relay output, provides one contact C, NO, NC. It takes one address in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
Addressable Modules MAD-412
Addressable control module of 2 relay outputs, provides two contacts C, NA, NC non-resettable. It takes two addresses in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
Addressable Modules MAD-421
Addressable monitor and control module with 1 supervised technical input for status indication of devices that provides NC or NO contact and 1 voltage-free relay output providing non-resettable C, NO, NC contact. It takes two addresses in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
Addressable Modules MAD-422
Addressable monitor and control module with of 2 supervised technical inputs, for the devices status signaling that provide NC or NO contact and 2 voltage-free relay outputs that provide two non-resettable C, NO, NC contacts. It takes four addresses in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
Addressable Modules MAD-431
Addressable control module of 1 monitored 24V output, for the activation of optical-acoustic signaling devices or maneuvers that require power, discriminating the fault of cut or short circuit in said line. It takes one loop address. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Allows installation without polarity. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
Addressable Modules MAD-432
Addressable control module of 2 supervised 24V outputs, for the activation of optical-acoustic signaling devices or maneuvers that require power, discriminating the fault of cut or short circuit in said line. It takes two loop addresses. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Allows installation without polarity. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
Addressable Modules MAD-441
Addressable monitor module of 1 conventional zone, allows connection of up to 20 conventional detectors and / or 32 conventional manual call points. Can identify between detector and manual call point alarm as well as between the fault by cutting or by short circuit of the zone. It takes one loop address. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Allows installation without polarity. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
Not sure which part you need?
Our technical team helps with system design, product selection and compatibility. Approved installation companies can also download datasheets and request quotations online.