Product catalogue
393 Detnov products from the 2026 range, supplied and supported in South Africa by Stella Fire.
30 products match “Call point”
Clear search and filters-
Addressable Manual Call Points MAD-452
Addressable manual call point. Includes protection cover TBD-200, surface suplement SMD-200 and test key RKEY- 200. Surface installation. Indoor use. Red color. CPR certificate EN 54-11. Dimensions: 85 x 89 x 35 mm.
-
Addressable Manual Call Points MAD-452-I
Addressable manual call point with built-in isolator. includes protection cover TBD-200, surface suplement SMD-200 and test key RKEY-200. Surface installation. Indoor use. Red color.CPR certificates EN 54-11 and EN 54-17. Dimensions: 89 x 85 x 60 mm.
-
Addressable Manual Call Points MAD-452-5ST
5 Addressable manual call point pack. Includes surface suplement SMD-200 and test key RKEY-200.Not includes protection cover TBD-200. Surface installation. Indoor use. Red color. CPR certificate EN 54-11. Dimensions: 89 x 85 x 60 mm per unit
-
Addressable Manual Call Points MAD-452-I-5ST
5 Addressable manual call point with built-in isolator. Includes surface suplement SMD-200 and test key RKEY-200. Not ncludes protection cover TBD-200. Surface installation. Indoor use. Red color.CPR certificates EN 54-11 and EN 54- 17. Dimensions: 89 x 85 x 60 mm.
-
Addressable Manual Call Points MAD-451-I
Addressable manual call point with built-in isolator. LED status indicator and test key. Red color. CPR certificates EN 54-11 and EN 54-17. Dimensions: 85 x 85 x 55 mm.
-
Conventional Manual Call Points PINTDET
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points PCD-200
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points PCD-200-5ST
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points TBD-200
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points SMD-200
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points PCD-100
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points TBD-450
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points SMD-450
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points WRP2-R-01
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points RP-GS2-02
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points TBD-450-IW
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points STI-13110ESP
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points STI-13620FR-ES
Conventional manual call point or associated mounting/protection accessory.
-
Conventional Manual Call Points BOX-2102
Conventional manual call point or associated mounting/protection accessory.
-
CAD-150 Control Panels - Red CAD-150-1 MINI (R)
Non expandable 1 loop and compact addressable fire alarm control panel. Up to 100 addresses (detectors, modules, sounders or manual call points). Self-search and self-diagnosis function. 250 programmable zones, 20 alarm and fault display zones via LEDs, 6.000 event log, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 voltage-free relay outputs configurable on board. LCD graphic display. 24V 500 mA auxiliary output. ABS plastic cabin with the possibility of recessing. Multilingual keyboard. Connectable to S-Network (up to 32 nodes) of control panels and repeaters via RS485 or fiber optics.
-
CAD-150 Control Panels - Red CAD-150-1 (R)
Non expandable 1 loop and compact addressable fire alarm control panel. Up to 250 addresses (detectors, modules, sounders or manual call points). Self-search and self-diagnosis function. 250 programmable zones, 20 alarm and fault display zones via LEDs, 6.000 event log, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 voltage-free relay outputs configurable on board. LCD graphic display. 24V 500 mA auxiliary output. ABS plastic cabin with the possibility of recessing. Multilingual keyboard. Connectable to S-Network (up to 32 nodes) of control panels and repeaters via RS485 or fiber optics.
-
CAD-150 Control Panels - Red CAD-150-2 (R)
Non expandable 2 loops and compact addressable fire alarm control panel. Up to 500 addresses (detectors, modules, sounders or manual call points). Self-search and self-diagnosis function. 250 programmable zones, 20 alarm and fault display zones via LEDs, 6.000 event log, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 voltage-free relay outputs configurable on board. LCD graphic display. 24V 500 mA auxiliary output. ABS plastic cabin with the possibility of recessing. Multilingual keyboard. Connectable to S-Network (up to 32 nodes) of control panels and repeaters via RS485 or fiber optics.
-
CAD-150 Control Panels - Red CAD-150-2-MB (R)
Non expandable 2 loops and compact addressable fire alarm control panel. Up to 500 addresses (250 adresses per loop: detectors, modules, sounders or manual call points). Self-search and self-diagnosis functions. 250 programmable zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. Metal box. Multilingual keyboard. Able to be networked to S-Network (32 nodes) via RS485 or fiber optics.
-
CAD-150 Control Panels - Red CAD-150-4 (R)
Non expandable 4 loops and compact addressable fire alarm control panel. Up to 1.000 addresses (250 addresses per loop: detectors, modules, sounders or manual call points). Self-search and self-diagnosis functions. 250 programmable zones, 6.000 event history logs, free configuration and maintenance software, configuration via USB port, 2 supervised sounder outputs and 2 configurable relay outputs. Graphic LCD display. Auxiliary output of 24V 500mA. Metal box. Multilingual keyboard. Able to be networked to S-Network (32 nodes) via RS485 or fiber optics.
-
CAD-150 Control Panels - Red CAD-150-8 (R)
Addressable fire alarm control panel with 4 loops expandable up to 8 loops, by means of 2 additional loops cards (TBUD-150). Up to 2,000 addresses (250 addresses per loop: detectors, modules, sounders or manual call points). Auto-search function, 250 programmable zones, 40 alarm and fault display zones via leds, 6.000 event history logs, free configuration and maintenance software, USB port configuration, 2 supervised sounder outputs and 2 free relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. Able to be networked to S-Network (32 nodes) via RS485 or fiber optics.
-
CAD-150 Control Panels - Red CAD-150-8-PLUS (R)
Addressable fire alarm control panel with 4 loops expandable up to 8 loops with printer built-in, by means of 2 additional loops card (TBUD-150). Up to 2,000 addresses (250 addresses per loop: detectors, modules, sounders or manual call points). Auto-search function, 250 programmable zones, 40 alarm and fault display zones via leds, 6.000 event history logs, free configuration and maintenance software, USB port configuration, 2 supervised sounder outputs and 2 free relay outputs. Graphic LCD display. Auxiliary output of 24V 500 mA. Modbus output for integrations, compatible with Detnov Cloud and Detnov Remote Center (remote maintenance and remote control).
-
Addressable Modules MAD-441
Addressable monitor module of 1 conventional zone, allows connection of up to 20 conventional detectors and / or 32 conventional manual call points. Can identify between detector and manual call point alarm as well as between the fault by cutting or by short circuit of the zone. It takes one loop address. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Allows installation without polarity. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
Addressable Modules MAD-442
Addressable monitor module of 2 conventional zones, allows the connection of up to 20 conventional detectors and / or 32 conventional manual call points per zone. Can identify between detector and manual call point alarm as well as between the fault by cutting or by short circuit of the zone. It takes two loop addresses. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Allows installation without polarity. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
Addressable Modules MAD-441-I
Addressable monitor module with built-in isolator of 1 conventional zone, allows the connection of up to 20 conventional detectors and / or 32 conventional manual call points. Can identify between detector and manual call point alarm as well as between the fault by cutting or by short circuit of the zone. It takes one loop address. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
-
Addressable Modules MAD-442-I
Addressable monitor module with built-in isolator of 2 conventional zones, allows the connection of up to 20 conventional detectors and / or 32 conventional manual call points per zone. Can identify between detector and manual call point alarm as well as between the fault by cutting or by short circuit of the zone. It takes two loop addresses. Requires 24 Vdc auxiliary power supply. LED status indicators. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18 and EN 54-17.
Not sure which part you need?
Our technical team helps with system design, product selection and compatibility. Approved installation companies can also download datasheets and request quotations online.