Addressable Modules
MAD-405-I
Addressable monitor module with built-in isolator of 5 supervised technical inputs for status indication of equipment providing NC or NO contact. It takes five loop addresses. Direct feed from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Includes mounting box. Dimensions: 172 x 170 x 48 mm. CPR certificate EN 54-18 and EN 54-17.
- Certification
- EN 54-18; EN 54-17
- Dimensions
- 172 x 170 x 48 mm
Quotations and technical files are for approved installation companies. Apply for installer access
Documents
Open in DownloadsNo datasheet has been added for this product yet. Contact technical support if you need one.
Manuals, certificates and CAD files for the MAD-405-I are available to approved installation companies.
Log in to see themMore addressable modules
See the full range-
MAD-401Addressable monitor module with 1 supervised technical input for device status indication providing NC or NO contact. It takes one address in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Non polarity installation. Consumption less than 300μA at rest. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
MAD-402Addressable monitor module with 2 supervised technical inputs for devices status signaling providing NC or NO contact. It takes two addresses in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
MAD-411Addressable control module for 1 relay output, provides one contact C, NO, NC. It takes one address in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
MAD-412Addressable control module of 2 relay outputs, provides two contacts C, NA, NC non-resettable. It takes two addresses in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
MAD-421Addressable monitor and control module with 1 supervised technical input for status indication of devices that provides NC or NO contact and 1 voltage-free relay output providing non-resettable C, NO, NC contact. It takes two addresses in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
MAD-422Addressable monitor and control module with of 2 supervised technical inputs, for the devices status signaling that provide NC or NO contact and 2 voltage-free relay outputs that provide two non-resettable C, NO, NC contacts. It takes four addresses in the loop. Fed directly from the loop. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Non polarity installation. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
MAD-431Addressable control module of 1 monitored 24V output, for the activation of optical-acoustic signaling devices or maneuvers that require power, discriminating the fault of cut or short circuit in said line. It takes one loop address. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Allows installation without polarity. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
-
MAD-432Addressable control module of 2 supervised 24V outputs, for the activation of optical-acoustic signaling devices or maneuvers that require power, discriminating the fault of cut or short circuit in said line. It takes two loop addresses. Requires 24 Vdc auxiliary power supply. LED status indicator. Connection through removable strips up to 2.5mm2 section. Possibility of being installed in DIN rail or flat to wall mounting in box BOX-ONE. Consumption less than 300μA at rest. Allows installation without polarity. Red color. Dimensions: 100 x 82 x 23 mm. CPR certificate EN 54-18.
Product information from the Detnov 2026 product list, page 32. Specifications may change; check the current datasheet before installation.