Addressable Detectors
200A and 300A series addressable detectors and variants.
Ranges Addressable Detectors
28 products
Clear search and filters-
DOD-320A
Addressable smoke detector, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200). Up to 5 configurable sensitivity profiles, manufacturing date and usage time recording. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. CPR certificate EN 54-7. Dimensions: 100 x 40 mm IP40.
-
DOTD-330A
Addressable smoke & heat detector, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Heat function (A2R). White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm. IP40.
-
DTD-310A
Addressable heat detector, incorporates verification algorithms. LED status and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200). By means of the PGD-300 programming tool can be configured with up to 5 classes A1, A2R (by default, A2S, BR and BS. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. CPR certificate EN 54-5. Dimensions: 100 x 40 mm. IP40.
-
DOD-220A
Addressable smoke detector, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7. Dimensions: 100 x 40 mm.
-
DOTD-230A
Addressable smoke & heat detector, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Allows installation without polarity. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm.
-
DTD-210A
Addressable heat (58°C fixed temperature and thermal rate of rise) detector, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Allows installation without polarity. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
-
DTD-215A
Addressable high temperature detector (fixed at 78ºC), with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Allows installation without polarity. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
-
DOD-320A-I
Addressable smoke detector with built-in isolator, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer, anti-theft system (only with Z-200). Up to 5 configurable sensitivity profiles, manufacturing date and usage time recording. White color. Requires connection base Z-200 or Z-200-H. CPR certificates EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
DOTD-330A-I
Addressable smoke & heat detector with built-in isolator, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Heat function (A2R). White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
DTD-310A-I
Addressable heat detector, incorporates verification algorithms with built-in isolator. LED status and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200). By means of the PGD-300 programming tool can be configured with up to 5 classes A1, A2R (by default, A2S, BR and BS. White color. Requires connection base Z-200 or Z-200-H. CPR certificates EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
DOD-220A-I
Addressable smoke detector with built-in isolator, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
-
DOTD-230A-I
Addressable smoke & heat detector with built-in isolator, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
-
DTD-210A-I
Addressable heat (58°C fixed temperature and thermal rate of rise) detector with built-in isolator, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
-
DTD-215A-I
Addressable high temperature detector (fixed at 78ºC) with built-in isolator, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. White color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
-
DOD-320A-B
Addressable smoke detector, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200-B). Up to 5 configurable sensitivity profiles, manufacturing date and usage time recording. Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. CPR certificate EN 54-7. Dimensions: 100 x 40 mm. IP40.
-
DOTD-330A-B
Addressable smoke & heat detector, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Heat function (A2R). Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200-B). CPR certificates EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm. IP40.
-
DTD-310A-B
Addressable heat detector, incorporates verification algorithms. LED status and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200). By means of the PGD-300 programming tool can be configured with up to 5 classes A1, A2R (by default, A2S, BR and BS. Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
-
DOD-220A-B
Addressable smoke detector, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7. Dimensions: 100 x 40 mm.
-
DOTD-230A-B
Addressable smoke & heat detector, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5 and EN 54-7. Dimensions: 100 x 40 mm.
-
DTD-210A-B
Addressable heat (58°C fixed temperature and thermal rate of rise) detector, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Allows installation without polarity. Requires base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
-
DTD-215A-B
Addressable high temperature detector (fixed at 78ºC), with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200.. Black color. Allows installation without polarity. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5. Dimensions: 100 x 40 mm.
-
DOD-320A-I-B
Addressable smoke detector with built-in isolator, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200-B). Up to 5 configurable sensitivity profiles, manufacturing date and usage time recording. Black color. Requires connection base Z-200-B or Z-200-B-H. CPR certificates EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
DOTD-330A-I-B
Addressable smoke & heat detector with built-in isolator, with dirtiness compensation and algorithm verification. Include Dust Proof Technology (DPT). Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Heat function (A2R). Black color. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200-B). CPR c ertificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
DTD-310A-I-B
Addressable heat detector with built-in isolator, incorporates verification algorithms. LED status and output for remote indicator PAD-20 or buzzer BUD-200, anti-theft system (only with Z-200). By means of the PGD-300 programming tool can be configured with up to 5 classes A1, A2R (by default, A2S, BR and BS. Black color.Requires connection base Z-200-B or Z-200-B-H. CPR certificates EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm. IP40.
-
DOD-220A-I-B
Addressable smoke detector with built-in isolator,, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Requires connection base Z-200-B or Z-200-B-H. Anti-theft system (only with Z-200). CPR certificate EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
-
DOTD-230A-I-B
Addressable smoke & heat detector with built-in isolator, with dirtiness compensation and algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificates EN 54-5, EN 54-7 and EN 54-17. Dimensions: 100 x 40 mm.
-
DTD-210A-I-B
Addressable heat (58°C fixed temperature and thermal rate of rise) detector with built-in isolator, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Requires base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
-
DTD-215A-I-B
Addressable high temperature detector (fixed at 78ºC) with built-in isolator, with algorithm verification. Led status indicator and output for remote indicator PAD-20 or buzzer BUD-200. Black color. Requires connection base Z-200 or Z-200-H. Anti-theft system (only with Z-200). CPR certificate EN 54-5 and EN 54-17. Dimensions: 100 x 40 mm.
Not sure which part you need?
Our technical team helps with system design, product selection and compatibility. Approved installation companies can also download datasheets and request quotations online.